Page 5 Rev. F, 02/11
Lock/Strike Installation for “B” and “D” Magnalocks
IMPORTANT!
PLEASE READ AND APPLY THIS INFORMATION WHEN ALIGNING/INSTALLING THE
LOCK AND STRIKE. THE ALIGNMENT TOLERANCES INDICATED FOR EACH LOCK
MODEL ARE CONSIDERED CRITICAL FOR THE PROPER OPERATION OF BOTH THE
MAGNETIC BOND SENSING AND DOOR POSITION SENSING SYSTEMS!
SENSOR RANGES (PHYSICAL POSITIONING):
The BondSTAT “B” and DPS “D” Magnalock “Secure Zone” sensing ranges for each lock
model is listed in Table A.
(The Figure 6 illustration is a visual reference to the sensing ranges outlined in Table A).
Secure Sensor Indication Range
(Dimensions from Center)
Model "X" (+/-) "Y" (+/-)
M32B/D 9/32" 1/8"
M62B/D 5/16" 1/8"
M82B/D 9/16" 1/8"
Table A
(+)
(+)
(-)
(+)
(-)
(-)
(+)
(-)
X
Y
0
0
Figure 6
5.2.5 In-swinging Door Installation
Figure 7 below illustrates a typical in-swinging door mounting configuration. This installation
requires the use of a face mount style Magnalock (i.e. M32F, M62F, or M82FB) and a “Z” bracket
(Z-32, Z-62, or Z-82) or an adjustable “ZA” bracket (ZA-32/62 or ZA-82) for offsetting the
mounting of the strike must be used. Follow the installation instructions provided with the “Z” or
“ZA” bracket product to correctly install the Magnalock in this arrangement.
THE M62F AND M82FB INCLUDE FIVE (5) MOUNTING HOLES FOR FLEXIBILITY
Figure 7
Z-Bracket or “ZA Bracket
(Dress cover not shown)
Strike Plate
Magnalock
Blind Nuts
and Mounting
Screws
Strike Mounting
Hardware and
T-Nut
Sex Bolt
Door Frame and Stop
Door
Bracket Mounting
Hardware
Page view 4