Securitron M82B User Manual Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
PN# 500-10420
Page 10 Rev. F, 02/11
SFP – Stop Filler Plate – The SFP bracket is designed for extending the door frame
mounting surface 1-1/4” [31.8mm]. Thicknesses available in 1/4” [6.4mm], 3/8”
[9.5mm], 1/2” [12.7mm] and 5/8” [15.9mm]. Lengths available in 8” [203mm] for M32
or M62 and 12” [305mm] for M82B Magnalocks.
UHB – Universal Header Bracket The UHB bracket is designed to extend the frame
width 1” [25.4mm] to 1-1/2” [38.1mm] deeper on steel and aluminum headers not wide
enough to mount the Magnalock. Lengths available in 8” [203mm] for M32 or M62 and
12” [305mm] for M82B Magnalocks.
Z-Bracket The “Z” bracket is designed for use with installations of “F” Series
Magnalocks for in-swinging doors and gates.
ZA-Bracket – The “ZA” bracket is designed to allow a full range of adjustability for use
with installations of “F” Series Magnalocks for in-swinging doors and gates.
7. SPECIALIZED STRIKES
The AOS Armature Offset strike is designed for offset drilling doors with mechanical
interference hardware present in the door structure. It is also accommodates errors that
may have occurred in the field from incorrect mounting placement. (See Section 5.2.5)
The ASS – Armature Split strike is designed for single lock/double door installation. There
is a reduced holding force when using the split strike. (See Section 5.2.5)
8. SPECIALIZED ACCESSORIES
8.1 Dress Covers
Single Magnalock Dress Covers – The covers are designed to meet architectural
finishes for matching specified installations. Available in four (4) architectural finishes.
Double Dress Covers – The covers are designed to fit over a double door/dual lock
installation. Available in two (2) architectural finishes.
8.2 Installation Tool Kit Securitron offers an installation tool kit which includes special drill
bits, a heavy duty drill guide, a blind nut collapsing tool, extra fasteners and hardware.
Metric is also available.
8.3 Tamper Proofing Special tamper proof screws are available for Magnalock and strike
armature mounting. The screws are pinned-socket hex head. A special hex wrench is
required and is available when purchasing the screws.
9. MAGNALOCK MAINTENANCE
9.1 Visual Inspection
Check the rubber washers for elasticity and proper pivoting. Tighten as required.
Check for build-up of debris on the Magnalock and strike armature. Clean as required.
Check for rust on the Magnalock and strike plate armature. Clean as required.
9.2 Cleaning Methods
Cleaning once a year is recommended.
Clean every six months where minor rusting occurs.
Clean every three months if rust conditions are severe.
Use a plastic dishwashing scrub pad to aid in the removal of rust.
DO NOT USE PETROLEUM BASED PRODUCTS FOR CLEANING
DO NOT USE STEEL WOOL BASED SCRUB PAD OR SANDPAPER
9.2.1 Indoor Applications
Apply rubbing alcohol onto a clean cloth and thoroughly wipe down the Magnalock and
strike plate armature.
9.2.2 Outdoor Applications
Apply a silicone based cleaner/lubricant onto a clean cloth and thoroughly wipe down
Magnalock and strike plate armature.
Example: Super Lube® Aerosol with SYNCOLON® (PTFE)
Part No.: 31040 ~ 6oz. / 31110 ~ 11 oz. / 32015 ~ 14 oz.
Phone: (631) 567-5300 / Website: www.super-lube.com
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 16

Comments to this Manuals

No comments