Securitron HHSR User Manual

Browse online or download User Manual for For Home Securitron HHSR. Securitron HHSR User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 6
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader
Tel 800.624.5625 [email protected]
in door opening solutions
© Copyright, 2011, all rights reserved PN# 500-16600
Page 1 Rev. D, 07/11
FULL LENGTH LOCK HOUSING MODELS HHD, HVD, HHSL AND HHSR
FOR M32, M62 AND M82 MAGNALOCKS – INSTALLATION INSTRUCTIONS
1. DESCRIPTION
Securitron’s full length Magnalock housings are furnished complete with a brushed stainless steel
cover, two (2) end caps, an aluminum mounting plate and mounting hardware. These housings
provide an attractive and secure lock installation option and are offered in three configurations:
HVD
VERTICAL MOUNT
DUAL LOCK
SINGLE DOOR
NON-HANDED
HHD
HORZONTAL MOUNT
DUAL LOCK
DOUBLE DOOR
NON-HANDED
HHSL/HHSR
HORIZONTAL MOUNT
SINGLE LOCK
SINGLE DOOR
HANDED (HHSR Shown)
2. OVERVIEW
Upon unpacking, an inventory should be made to ensure that all the required components and
hardware have been included. Along with these instructions, the Full Length Housing package
should contain the following items:
HOUSING ASSEMBLY:
1X MOUNTING PLATE +
1X COVER (PRE-ASSEMBLED)
HARDWARE PACK(S):
2X FOR HVD & HHD
1X FOR HHSL & HHSR
2X END CAPS
(
ALL MODELS
)
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1

Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solution

Page 2 - Page 2 Rev. D, 07/11

PN# 500-16600 Page 2 Rev. D, 07/11 INCLUDED HARDWARE (Quantities shown are per single pack): 2X All Models 2X All Models 2X All Models

Page 3 - Page 3 Rev. D, 07/11

PN# 500-16600 Page 3 Rev. D, 07/11 Figure 2 4.1 STRIKES While maintaining the housing assembly in the desired position, mark the center of t

Page 4

PN# 500-16600 Page 4 Rev. D, 07/11 Figure 3 - HHD, HVD, HHSL or HHSR-32 Figure 4 - HHD, HVD, HHSL or HHSR-62/82 Figure 5 - M62 or M82 On A

Page 5 - Page 5 Rev. D, 07/11

PN# 500-16600 Page 5 Rev. D, 07/11 Once the mounting plate is suitably positioned, it may be used as a template to mark/drill the holes require

Page 6 - Page 6 Rev. D, 07/11

PN# 500-16600 Page 6 Rev. D, 07/11 NOTE: Mounting holes are configured to provide a flush mount up to a #14 X 4” Flathead SMS/wood screw. The

Related models: HHSL | HVD | HHD |

Comments to this Manuals

No comments